Get in touch with TIME Company
Pressure Unit and Class Converter
Enter one pressure and read it in all three units. The two limits that get merged on most enquiries are kept in separate rows: the pressure up to which a coupling can be connected while the circuit is live, and the maximum working pressure the standard permits for couplings built to it.
Enter a value and the conversion appears here.
Reference Limits
| Limit | MPa | bar | psi (converted) |
|---|---|---|---|
| Connect-under-pressure limit, ISO 15171-2 | 40 | 400 | about 5,800 |
| Maximum working pressure permitted by ISO 15171-2 | up to 63 | up to 630 | about 9,140 |
The second figure depends on materials, design, working conditions and application. It is what the standard permits, not a rating carried by every part. Per-model ratings are confirmed on the drawing.
Back to hydraulic test fittings · Identify your interface · Request a quote